CAN Arbitration ID for ICL3 is 0x615 .

Its sent out by the instrument cluster at a refresh rate of 200ms.

  • Byte 0 - Bitfield
    • Bit 0 - TQ_ACCIN_CAN [0]
    • Bit 1 - TQ_ACCIN_CAN [1]
    • Bit 2 - TQ_ACCIN_CAN [2]
    • Bit 3 - TQ_ACCIN_CAN [3]
    • Bit 4 - TQ_ACCIN_CAN [4]
      Torque Offset For Air Conditioning Compressor
    • Bit 5 - LV_REQ_TCO_L
      Request For Lowering Cooling Temp (c_tco_bol_ect)
    • Bit 6 - LV_ACCIN
      Air Conditioning Compressor Status (0=off, 1=on)
    • Bit 7 - LV_ACIN
      Air Conditioning Request (0=off, 1=on)
  • Byte 1 - Bitfield
    • Bit 0 - LV_REQ_HEAT
      Increased Heat Request
    • Bit 1 - LV_TOW
      Trailer Operation Mode
    • Bit 2 - LV_LGT
      Day / Night Lighting
    • Bit 3 - LV_HS
      Hood Switch
    • Bit 4 - N_ECF [0]
    • Bit 5 - N_ECF [1]
    • Bit 6 - N_ECF [2]
    • Bit 7 - N_ECF [3]
      Electric Cooling Fan Level
  • Byte 2 -
  • Byte 3 - TAM_CAN
    Ambient Temperature
  • Byte 4 - Bitfield
    • Bit 0 - LV_DOOR - Door Switch
    • Bit 1 - LV_HBR - Hand Brake Switch
    • Bit 2 -
    • Bit 3 -
    • Bit 4 -
    • Bit 5 - LV_REQ_TCO_L -
    • Bit 6 - LV_ACCIN - Air Conditioning Compressor Status (0=off, 1=on)
    • Bit 7 - LV_ACIN - Air Conditioning Request
  • Byte 5 -
  • Byte 6 -
  • Byte 7 -