Advertising:
CAN Bus ID 0x615 ICL3: Difference between revisions
From MS4X Wiki
No edit summary |
No edit summary |
||
Line 30: | Line 30: | ||
**'''Bit 7 - N_ECF [3]''' | **'''Bit 7 - N_ECF [3]''' | ||
**:Electric Cooling Fan Level | **:Electric Cooling Fan Level | ||
*'''Byte 2 - ''' | *'''Byte 2 - Bitfield''' | ||
**'''Bit 0 - [0]''' | |||
**'''Bit 1 - [1]''' | |||
**'''Bit 2 - [2]''' | |||
**'''Bit 3 - [3]''' | |||
**'''Bit 4 - [4]''' | |||
**'''Bit 5 - [5]''' | |||
**'''Bit 6 - Request Raised Idle''' | |||
**'''Bit 7 - unused''' | |||
*'''Byte 3 - TAM_CAN''' | *'''Byte 3 - TAM_CAN''' | ||
*:Ambient Temperature | *:Ambient Temperature |
Revision as of 21:37, 25 May 2021
CAN Arbitration ID for ICL3 is 0x615 .
Its sent out by the instrument cluster at a refresh rate of 200ms.
- Byte 0 - Bitfield
- Bit 0 - TQ_ACCIN_CAN [0]
- Bit 1 - TQ_ACCIN_CAN [1]
- Bit 2 - TQ_ACCIN_CAN [2]
- Bit 3 - TQ_ACCIN_CAN [3]
- Bit 4 - TQ_ACCIN_CAN [4]
- Torque Offset For Air Conditioning Compressor
- Bit 5 - LV_REQ_TCO_L
- Request For Lowering Cooling Temp (c_tco_bol_ect)
- Bit 6 - LV_ACCIN
- Air Conditioning Compressor Status (0=off, 1=on)
- Bit 7 - LV_ACIN
- Air Conditioning Request (0=off, 1=on)
- Byte 1 - Bitfield
- Bit 0 - LV_REQ_HEAT
- Increased Heat Request
- Bit 1 - LV_TOW
- Trailer Operation Mode
- Bit 2 - LV_LGT
- Day / Night Lighting
- Bit 3 - LV_HS
- Hood Switch
- Bit 4 - N_ECF [0]
- Bit 5 - N_ECF [1]
- Bit 6 - N_ECF [2]
- Bit 7 - N_ECF [3]
- Electric Cooling Fan Level
- Bit 0 - LV_REQ_HEAT
- Byte 2 - Bitfield
- Bit 0 - [0]
- Bit 1 - [1]
- Bit 2 - [2]
- Bit 3 - [3]
- Bit 4 - [4]
- Bit 5 - [5]
- Bit 6 - Request Raised Idle
- Bit 7 - unused
- Byte 3 - TAM_CAN
- Ambient Temperature
- Byte 4 - Bitfield
- Bit 0 - LV_DOOR - Door Switch
- Bit 1 - LV_HBR - Hand Brake Switch
- Bit 2 - LV_SUSP [0]
- Bit 3 - LV_SUSP [1]
- Suspension Switch
- Bit 4 -
- Bit 5 - LV_REQ_TCO_L -
- Bit 6 - LV_ACCIN - Air Conditioning Compressor Status (0=off, 1=on)
- Bit 7 - LV_ACIN - Air Conditioning Request
- Byte 5 -
- Byte 6 -
- Byte 7 -