ICL3 0x615

Refresh Rate: 200ms

  • Byte 0 - Bitfield
    • Bit 0 - TQ_ACCIN_CAN - Torque Offset For Air Conditioning Compressor (Bit 0)
    • Bit 1 - TQ_ACCIN_CAN - Torque Offset For Air Conditioning Compressor (Bit 1)
    • Bit 2 - TQ_ACCIN_CAN - Torque Offset For Air Conditioning Compressor (Bit 2)
    • Bit 3 - TQ_ACCIN_CAN - Torque Offset For Air Conditioning Compressor (Bit 3)
    • Bit 4 - TQ_ACCIN_CAN - Torque Offset For Air Conditioning Compressor (Bit 4)
    • Bit 5 - LV_REQ_TCO_L - Request For Lowest Cooling Temp (c_tco_bol_ect)
    • Bit 6 - LV_ACCIN - Air Conditioning Compressor Status (0=off, 1=on)
    • Bit 7 - LV_ACIN - Air Conditioning Request
  • Byte 1 - Bitfield
    • Bit 0 - LV_REQ_HEAT - Increased Heat Request
    • Bit 1 - LV_TOW - Trailer Operation Mode
    • Bit 2 - LV_LGT - Day / Night Lighting
    • Bit 3 - LV_HS - Hood Switch
    • Bit 4 - N_ECF - Electric Cooling Fan Level (Bit 0)
    • Bit 5 - N_ECF - Electric Cooling Fan Level (Bit 1)
    • Bit 6 - N_ECF - Electric Cooling Fan Level (Bit 2)
    • Bit 7 - N_ECF - Electric Cooling Fan Level (Bit 3)
  • Byte 2 -
  • Byte 3 - TAM_CAN - Ambient Temperature
  • Byte 4 - Bitfield
    • Bit 0 - LV_DOOR - Door Switch
    • Bit 1 - LV_HBR - Hand Brake Switch
    • Bit 2 -
    • Bit 3 -
    • Bit 4 -
    • Bit 5 - LV_REQ_TCO_L -
    • Bit 6 - LV_ACCIN - Air Conditioning Compressor Status (0=off, 1=on)
    • Bit 7 - LV_ACIN - Air Conditioning Request
  • Byte 5 -
  • Byte 6 -
  • Byte 7 -