Temperature Sensors
M50 IAT Sensor
V | °C |
---|---|
0.098 | 140.3 |
0.137 | 129.8 |
0.215 | 110.3 |
0.274 | 99.8 |
0.352 | 90.0 |
0.450 | 80.3 |
0.586 | 69.8 |
0.782 | 60.0 |
1.017 | 50.3 |
1.721 | 30.0 |
2.170 | 20.3 |
2.698 | 9.8 |
3.226 | 0.0 |
3.715 | -9.8 |
4.126 | -20.3 |
4.439 | -30.0 |
MS42/3 IAT sensor:
V | °C |
---|---|
0.215 | 142.5 |
0.274 | 129.8 |
0.469 | 110.3 |
0.606 | 99.8 |
0.782 | 90.0 |
1.017 | 80.3 |
1.310 | 69.8 |
1.662 | 60.0 |
2.092 | 50.3 |
3.089 | 30.0 |
4.008 | 9.8 |
4.341 | 0.0 |
4.595 | -9.8 |
4.751 | -20.3 |
4.927 | -39.8 |
4.966 | -48.0 |
MS45 IAT Sensor
V | °C |
---|---|
0.195 | 129.8 |
0.274 | 114.8 |
0.450 | 95.3 |
0.567 | 84.8 |
0.743 | 75.0 |
1.232 | 54.8 |
1.564 | 45.0 |
1.975 | 35.3 |
2.952 | 15.0 |
3.891 | -5.3 |
4.243 | -5.3 |
4.517 | -15.0 |
4.517 | -24.8 |
4.712 | -35.3 |
4.771 | -39.8 |
4.966 | -48.0 |