Advertising:
TunerPro MS43 Community Patchlist: Difference between revisions
From MS4X Wiki
Line 33: | Line 33: | ||
=M3/M5 Cluster LEDs= | =M3/M5 Cluster LEDs= | ||
=Extended DS2 Logging= | =Extended DS2 Logging= | ||
*'''[PATCH] DS2 Logging Feature Enhancement''' - | |||
This patch contains a new logging command (0B B0) that extends the stock (0B 03) with the following values: | |||
*Ignition timing for all cylinders | |||
*Fuel injector pulse width for bank 2 | |||
*Calculated manifold air pressure | |||
*Active VO table | |||
*Filtered load values | |||
*Calculated gear | |||
*Rear O2 voltage input | |||
=MAF Sensor Hack= | =MAF Sensor Hack= | ||
*'''[PATCH] MAF Sensor Hack 2048kg/h''' | *'''[PATCH] MAF Sensor Hack 2048kg/h''' | ||
*'''id_maf_tab''' - MAF sensor table 1x256 | *'''id_maf_tab''' - MAF sensor table 1x256 | ||
*'''id_maf_tab''' - MAF sensor table 16x16 | *'''id_maf_tab''' - MAF sensor table 16x16 |
Revision as of 20:33, 19 May 2019
TunerPro offers a very good method of editing flash files with its "Patch" function.
We used this feature to create an "All-In-One" solution for editing engine displacement independant functions, like EWS or checklsum delete, M3 cluster warumup and shiftlights,etc.
ECU Information
- UIF Vehicle Identification Number
- UIF Software Number
- UIF Service Number
- UIF Assembly Number
- ECU Number
- ISN Value
- Softwareversion
Immobilizer Bypass
- Immobilizer Bypass - Disables the EWS / immobilizer checks of the ecu
- Clear Immobilizer Data - Clear all EWS / immobilizer related data to realign the ECU with EWS module via INPA. Requires bootmode flash!
Checksum Bypass
- Checksum Bypass - Disables both checksums for the calibration data section
Launch Control
- [PATCH] Launch Control - Implements a launch control that sets an additional revlimiter while meeting the following calibration values
- c_conf_lc - Configuration switch to enable or disable the launch control feature
- c_n_lc_max - Maximum engine speed while the launch control is engaged
- c_pvs_lc_min - Minimum accellerator pedal position for the launch control to be engaged
- c_vs_lc_max - Maximum vehicle speed for the launch control to be engaged
- c_tco_lc_min - Minimum coolant temperature for the launch control to be engaged
M3/M5 Cluster LEDs
Extended DS2 Logging
- [PATCH] DS2 Logging Feature Enhancement -
This patch contains a new logging command (0B B0) that extends the stock (0B 03) with the following values:
- Ignition timing for all cylinders
- Fuel injector pulse width for bank 2
- Calculated manifold air pressure
- Active VO table
- Filtered load values
- Calculated gear
- Rear O2 voltage input
MAF Sensor Hack
- [PATCH] MAF Sensor Hack 2048kg/h
- id_maf_tab - MAF sensor table 1x256
- id_maf_tab - MAF sensor table 16x16